Specifications
- Xenox C100 is available in different models: with rotating anode tube or stationary one & Image Intensifier 9” or 12” (only for rotating version)
- Horizontal run 210 mm
- Arc orbital movement 135°
- WIG-WAG ±12,5°
- C-arm depth 690 mm
- S. I. D. 988 mm/980 mm/920 mm
- Arm rotation around horizontal axis ±270°
- Generator power in DC current 5 kW (3,5kW@115 Vac)
- Generator operating frequency 40 kHz
- KV range 40 -h 120 kV
- Max. current in continuous fluoroscopy 8,0 mA
- Max. current in «SNAPSHOT» fluoroscopy 30 mA
- Max. current in HCF with DFG (HRP)30 mA
- Max. current in pulsed fluorography with DFG (HRP)60 mA@230 Vac;45 mA@115 Vac
- Max. current in digital graphy-mode with DFG (HRP)60 mA@230 Vac;45 mA@115 Vac
- Max. current in radiography (hi-rad) 35 mA @ 115 Vac ; 50 mA @ 230 Vac
- Max. mas in radiography 90 mAs @ 115 Vac -;125 mAs @ 230 Vac
- Max Fluoroscopy time H.U. Safety after 28 min. of fluoroscopy @120 kV, 5 mA (600W)
- Membrane keyboard with alphanumeric touch-screen 5.7” LCD display for all the operative parameters and error messages. Microprocessor management. Keyboard can be rotated of ± 60°
Operating Modes and Functionality
OPERATING MODALITIES OF MEMORY
CONTINUOS FLUOROSCOPY
PULSED FLUOROSCOPY (12/sec, 6/sec, 3/sec, 1/sec – without acquisition on hard disk)
DIGITAL SNAPSHOT
FLUOROSCOPY mA (1/2): (range: 0,25-4 mA)
RADIOGRAPHY: 2 points technique (kV & mAs)
Digital video processing
- Number of images on Hard Disk: about 55.000 (Hard Disk 128 GB)
- Video output: 1 x HDMI 1960×1200
- Image format on the working memory: 1024 x 1024 x 12 bit
- Number of monitors: 1 24“ LCD
- Optional: Hard Disk of 256 GB (about 110.000 images)
Software:
Functions: selection of anatomic programs; recursive filter (1,2,4,8,16); edge enhancement Smooth, Normal, Sharp in post processing; smart filter with «motion detection»; grey scale inversion; brightness and contrast; virtual collimator, horizontal and vertical flip; electronic rotation at 1° step; Electronic zoom factor from 1,2 to 3; Electronic lens factor from 1,2 to 3; Overview (4,9,16 images); Text editing; Dose report; Patients archive; Interface for network Ethernet TCP/IP; Export single BMP image on USB
Measure tools (included in basic configuration): length, angles, stenosis, length calibration on reference object; text overlay
Features
- 12″ and 9″ image intensifier option available
- High Frequency monoblock X-ray generator 5 KW
- 1k CCD camera delivers sharp and detail-rich images
- Keyboard can be rotated of ± 60°
- Modular configurations even after sales
- HD storage memory
- Full Dicom (optional)
- Triple footswitch fluoroscopy control
- 210 mm horizontal C-arm run, with manual brake for locking
- Orbital movement 135°
- 270° on each side arm rotation, with manual brake for locking
- 12° on each side C-arm swivelling with manual brake for locking
- Monitor trolley with 24″ LCD Monitor
- Realtime and post processing features
Applications
- Traumatology
- Orthopedics
- Digestive system
- Generic Surgery
- Biliary drainage and stenting
- Image guided biopsy
- Neonatology and pediatrics
- Lithotripsy
Options
- DICOM package: DICOM VERIFY (SCU/SCP), DICOM STORAGE, DICOM WORKLIST (SCU), DICOM PRINT (SCU), DICOM CDR/D VD, DICOM QUERY/RETRIEVE (SCU), DICOM MPPS (CPU), DICOM STORAGE COMMITMENT (SCU), DICOM DOSE STRUCTURED REPORT
- HARD DISK SSD 256 GB (about 110.000 images)
- Thermal printer
- Patient radiation dose measuring device (DAP chamber)
- Laser localizer for centering the anatomical area to be examined on the I.I. side
- 24×30 cm or 18×24 cm or 10×12’’ Cassette Holder (9” I.I.)
- 35×35 cm Cassette Holder (12” 1.1.)